{"title":"Photovoltaics","description":"","products":[{"product_id":"photovoltaik-kaco-powador-protect-grid-protectiction-kaco-powador-protect-ext-na-schutz","title":"Kaco Powador-protect grid protection Kaco Powador-protect ext. NA protection","description":"\u003ch1\u003eKaco Powador-protect ext. NA protection\u003c\/h1\u003e\n\u003ch3\u003e Protection device and control unit for network management in photovoltaic systems.\u003c\/h3\u003e\n\u003ch2\u003e Data sheets\u003c\/h2\u003e\n\u003ch3\u003e \u003ca href=\"https:\/\/solarwatt.canto.global\/direct\/document\/ag82taarep2t33msgnm9qeae35\/W-hOjAy0WvBCuIA8WrHBIiEzS9c\/original?content-type=application%2Fpdf\u0026amp;name=Datenblatt+Kaco+ext.+NA-Schutz+Powador-protect.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eData sheet Kaco ext. NA protection Powador-protect\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003ch2\u003e Assembly instructions\u003c\/h2\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/solarwatt.canto.global\/direct\/document\/8non5rgcll7k7efm79shaspk4e\/mnnQP85_nmuiZhg6TbWdOsEQ5Lc\/original?content-type=application%2Fpdf\u0026amp;name=Anwendungshinweise+Kaco+ext.+NA+Schutz+Powador-protect.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eApplication instructions Kaco ext. NA protection Powador-protect\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"https:\/\/solarwatt.canto.global\/direct\/document\/4vorvuucjl2ar5d4cq1upcge2u\/x3IuUYYGGQa2WOQfayUKQ06LmFM\/original?content-type=application%2Fpdf\u0026amp;name=Installationsanleitung+Kaco+ext.+NA-Schutz+Powador-protect.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eInstallation instructions Kaco ext. NA protection Powador-protect\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e Description\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eThe advantage of integrated inverter coupling switches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e KACO new energy inverters come standard with coupling switches that are directly controlled by the Powador-protect. This means for you:\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e No costs for materials, installation and operation of external coupling switches\u003c\/li\u003e\n\n\u003cli\u003e Simple and risk-free calculation without hidden AC costs.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e This is how you meet the requirements for grid and system protection according to the low-voltage guideline VDE-AR-N 4105. Grid protection is mandatory therein for photovoltaic systems with a capacity of 30 kilowatts or more.\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eAll guidelines\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eAt the same time, the Powador-protect allows you to comply with feed-in management regulations according to the German Renewable Energy Sources Act (EEG). Remote power limitation is required for systems of 30 kilowatts and above. The Powador-protect evaluates the signals from a ripple control receiver and transmits them directly to up to 31 inverters. Even in smaller installations, consider using this device: This way, you can avoid the otherwise mandatory continuous power limitation!\u003c\/p\u003e\n\u003cp\u003e Furthermore, the properties of the Powador-protect are advantageous in installations on the medium-voltage network. Here, the Powador-protect serves as an intermediate protection device, since protection testing is not possible with a large number of string inverters or if an inverter test strip is missing.\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e Network and plant protection, feed-in management\u003c\/li\u003e\n\n\u003cli\u003e Intermediate protection according to the 4th amendment to the medium voltage directive\u003c\/li\u003e\n\n\u003cli\u003e Individual voltage and frequency settings\u003c\/li\u003e\n\n\u003cli\u003e Integrated connection for a ripple control receiver\u003c\/li\u003e\n\n \u003cli\u003eControl of the inverter coupling switches, no additional AC costs\u003c\/li\u003e\n\n\u003cli\u003e Minimizing the cabling effort in the meter cabinet and in the sub-distribution board\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"SolarZiel","offers":[{"title":"Default Title","offer_id":52575603654993,"sku":"1126558","price":532.4,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7922\/1841\/files\/knu9ocylhl-product-picture-kaco-powador-protect.png?v=1765317042"},{"product_id":"montage-ufr1001e-von-ziehl","title":"UFR1001E from Ziehl","description":"\u003ch2\u003e Network and plant protection UFR1001E from Ziehl\u003c\/h2\u003e\n\u003cp\u003e Compact and universally adjustable for all standards – the Ziehl UFR1001E NA monitor. For systems \u0026gt;30 kVA, the\u003c\/p\u003e \u003cp\u003eNetwork and system protection is required as an external component. Here, either a completely pre-wired unit can be selected.\u003c\/p\u003e\n\u003cp\u003e can be used, or, if a suitable interface is available on the inverter, its mains relay can also be controlled directly.\u003c\/p\u003e\n\u003cp\u003e The complete boxes are available as separate items here in the shop. For the cost-effective direct control option.\u003c\/p\u003e\n\u003cp\u003e The Ziehl UFR1001E is ideally suited.\u003c\/p\u003e\n\u003ch3\u003e Product features:\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003e Quick selection of all common standards on the display\u003c\/li\u003e\n\n\u003cli\u003e easy DIN rail mounting\u003c\/li\u003e\n\n\u003cli\u003e Complies with VDE-AR-N 4105:2018-11 and VDE-AR-N 4110:2018-11\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cul\u003e\n\n\u003cli\u003e \u003ca href=\"https:\/\/www.ziehl.com\/de\/produkte\/dl\/Datenblatt-2524\/?task=download\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eData sheet Ziehl NA protection UFR1001E\u003c\/a\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003ca href=\"https:\/\/www.ziehl.com\/de\/produkte\/dl\/Betriebsanleitung-2510\/?task=download\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eOperating instructions Ziehl UFR1001E\u003c\/a\u003e\n\u003c\/li\u003e\n\n \u003cli\u003e\u003ca href=\"https:\/\/www.ziehl.com\/de\/downloads\/dl\/UFR1001E_KA_QG_ZIEHL_20220324pdf-3558\/?task=download\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eQuick Guide Ziehl UFR1001E\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e \u003ca href=\"https:\/\/www.ziehl.com\/de\/produkte\/dl\/Konformitaetserklaerung_IEC_60255-3074\/?task=download\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eDeclaration of Conformity Ziehl UFR1001E\u003c\/a\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003ca href=\"https:\/\/www.ziehl.com\/de\/produkte\/dl\/Deutschland_VDEARN_4105201108_Niederspannung-1772\/?task=download\"\u003eVDE AR-N 4105:2018-11\u003c\/a\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003ca href=\"https:\/\/www.ziehl.com\/de\/produkte\/dl\/Deutschland_VDEARN_4105201108_Niederspannung-1772\/?task=download\"\u003eVDE-AR-N 4105:2011-08\u003c\/a\u003e\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e","brand":"SolarZiel","offers":[{"title":"Default Title","offer_id":52575625707857,"sku":"204707-00.01","price":548.4,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7922\/1841\/files\/mfs2ebgvnr-bi-sma-spannung-frequenzrelais-ufr1001e.jpg?v=1765317362"},{"product_id":"montage-bender-vmd460-na-d-2-netz-und-anlagenschutz","title":"Bender VMD460-NA-D-2, network and plant protection","description":"\u003ch1\u003eBender VMD460-NA-D-2, network and plant protection\u003c\/h1\u003e\u003cp\u003e for the grid decoupling of generation plants at\u003c\/p\u003e\u003cp\u003e Low and medium voltage network, monitoring\u003c\/p\u003e\u003cp\u003e the string and line voltage and the\u003c\/p\u003e\u003cp\u003e connected dome switch, illuminated\u003c\/p\u003e\u003cp\u003e Graphic display, DIN rail mounting\u003c\/p\u003e\u003cp\u003e Dimensions (WxHxD): 108x90x74 mm, Weight: 0.36 kg\u003c\/p\u003e\u003cp\u003e \u003ca href=\"https:\/\/www.bender.de\/fileadmin\/content\/Products\/d\/d\/VMD460-NA_D00001_D_XXDE.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eDatasheet \/ Manual\u003c\/a\u003e\u003cbr\u003e \u003ca href=\"https:\/\/www.optec.ch\/de\/downloads?cmd=download\u0026amp;downloadid=1102\u0026amp;file=Bender+VMD460-NA+Anleitung+deutsch\"\u003eVMD460-NA\u003c\/a\u003e\u003c\/p\u003e","brand":"SolarZiel","offers":[{"title":"Default Title","offer_id":52575625773393,"sku":"wg24800010","price":613.6,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7922\/1841\/files\/vdnxeg3tsa-24800010-1.jpg?v=1765317363"},{"product_id":"montage-enwitec-feed-guard-na-schutz-bis-43-5-kva","title":"Enwitec Feed-Guard NA protection up to 43.5 kVA","description":"\u003ch1\u003e Enwitec Feed-Guard NA protection up to 43.5 kVA\u003c\/h1\u003e\n\u003cp\u003e Central grid protection and coupling switch for PV\u003c\/p\u003e\n\u003cp\u003e Systems up to 43.5 kVA (cos φ 0.9) with all-pole\u003c\/p\u003e\n\u003cp\u003e Network separation, suitable for TT and TN-S networks,\u003c\/p\u003e\n\u003cp\u003e Compliant with VDE AR-N-4105:2018; ready for connection\u003c\/p\u003e\n\u003cp\u003e Unit, contains NA protection relay type ABB, dome-\u003c\/p\u003e\n\u003cp\u003e ABB XT1C switch, and undervoltage release\u003c\/p\u003e\n\u003cp\u003e and buffer module 24VDC.\u003c\/p\u003e\n\u003cp\u003e Maximum active power output of the generating plant: 39 kW.\u003c\/p\u003e\n\u003cp\u003e Dimensions (WxHxD): 360x720x201mm, Weight: 20kg\u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/enwitec.eu\/wp-content\/uploads\/10014290_Manual_NA-Schutz-2019_DE_V1.0_HQ.pdf?lang=en\" target=\"_blank\" rel=\"noreferrer noopener\"\u003emanual\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"https:\/\/enwitec.eu\/wp-content\/uploads\/19_10_16_10014057_feedguard_43.5_V1.0.pdf\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"SolarZiel","offers":[{"title":"Default Title","offer_id":52575625806161,"sku":"wg24900291","price":1725.23,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7922\/1841\/files\/kytzlv6kbr-24900291-1.jpg?v=1765317363"},{"product_id":"montage-enwitec-feed-guard-na-schutz-bis-69-kva","title":"Enwitec Feed-Guard NA protection up to 69 kVA","description":"\u003ch1\u003e Enwitec Feed-Guard NA protection up to 69 kVA\u003c\/h1\u003e\n\u003cp\u003e Central grid protection and coupling switch for PV\u003c\/p\u003e\n\u003cp\u003e Systems up to 69 kVA (cos φ 0.9) with all-pole\u003c\/p\u003e\n\u003cp\u003e Network separation, suitable for TT and TN-S networks,\u003c\/p\u003e\n\u003cp\u003e Compliant with VDE AR-N-4105:2018. Ready for connection.\u003c\/p\u003e\n\u003cp\u003e Unit, contains NA protection relay type ABB, dome-\u003c\/p\u003e\n\u003cp\u003e ABB XT1C switch, and undervoltage release\u003c\/p\u003e\n\u003cp\u003e and buffer module 24VDC.\u003c\/p\u003e\n\u003cp\u003e Maximum active power output of the generating plant: 62 kW.\u003c\/p\u003e\n\u003cp\u003e Dimensions (WxHxD): 360x720x201mm, Weight: 20kg\u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/enwitec.eu\/wp-content\/uploads\/10014290_Manual_NA-Schutz-2019_DE_V1.0_HQ.pdf?lang=en\" target=\"_blank\" rel=\"noreferrer noopener\"\u003emanual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/enwitec.eu\/wp-content\/uploads\/10014041_Datenblatt_NA-Schutz-NA4105-PV-69KVA-TNS_TT_1.2.pdf\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"SolarZiel","offers":[{"title":"Default Title","offer_id":52575625838929,"sku":"wg24900292","price":1994.45,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7922\/1841\/files\/kvjftq0ybr-24900292-1.jpg?v=1765317366"},{"product_id":"montage-enwitec-na-schutz-vde-ar-n-4105-2018-11-172-5-kva","title":"Enwitec NA protection VDE-AR-N 4105:2018-11; 172.5kVA","description":"\u003ch1\u003e Enwitec NA protection VDE-AR-N 4105:2018-11; 172.5kVA\u003c\/h1\u003e\n\u003cp\u003e Central grid protection and coupling switch for PV\u003c\/p\u003e \u003cp\u003eSystems up to 172.5 kVA (cos φ 0.9) with all-pole\u003c\/p\u003e\n\u003cp\u003e Network separation, suitable for TT and TN-S networks,\u003c\/p\u003e\n\u003cp\u003e compliant with VDE AR-N-4105:2018-11.\u003c\/p\u003e\n\u003cp\u003e Ready-to-connect unit, includes NA protection relay\u003c\/p\u003e\n\u003cp\u003e Type Tele NA003-M64, coupling switch, as well as\u003c\/p\u003e\n\u003cp\u003e Undervoltage release and buffer module 24VDC.\u003c\/p\u003e\n\u003cp\u003e Input and output terminals 35-185mm²,\u003c\/p\u003e\n\u003cp\u003e Cable entries cable grommet M75\u003c\/p\u003e\n\u003cp\u003e Maximum active power output of the generating plant: 155 kW.\u003c\/p\u003e\n\u003cp\u003e Dimensions (WxHxD): 360x720x230mm, Weight: 15.4kg\u003c\/p\u003e\n\u003cp\u003e Note: Power limit VDE-AR-N 4105: 2018-11\u003c\/p\u003e\n\u003cp\u003e at 135 kW, when the 135 kW limit is exceeded\u003c\/p\u003e\n\u003cp\u003e A vote with the network operator is required.\u003c\/p\u003e\n\u003cp\u003e take place!\u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/enwitec.eu\/wp-content\/uploads\/10014290_Manual_NA-Schutz-2019_DE_V1.0_HQ.pdf?lang=en\" target=\"_blank\" rel=\"noreferrer noopener\"\u003emanual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/solar-distribution.baywa-re.de\/out\/media\/04-000612_enwitec_NA-Schutz_Standardtypen_DE_Nov_2023.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"SolarZiel","offers":[{"title":"Default Title","offer_id":52575625904465,"sku":"wg24900296","price":2376.55,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7922\/1841\/files\/33gmkes2il-24900296-1.jpg?v=1765317365"}],"url":"https:\/\/shop.solarziel.ch\/en\/collections\/kabelfuhrung-kopie.oembed","provider":"SolarZiel","version":"1.0","type":"link"}